Home > Professional New > DEEP BASEMENT - Single Side Shuttering

DEEP BASEMENT - Single Side Shuttering

Tri product comprehensive system to resist hydrostatic pressure in fully submerged condition.

  • RAFT-EPDM EXTREMELY FLEXIBLE AND TOUGH, RESISTS HYDROSTATIC PRESSURE.
  • RETAINING WALL-EXTENSA EXCELLENT ADHESION ON VERTICAL SURFACES
  • SYSTEM LIFE EXPECTANCY- 15 YEARS
  • REINFORCEMENT TO RETAINING WALL - SAMSHIELD FOR COMPLICATED CONCRETE PROFILE

Method Statement

Raft Dr. Fixit Flexshield

SURFACE PREPARATION

Clean the surface thoroughly to get rid of all contaminants. Remove all surface imperfections and repair with a polymer modified mortar using Dr. Fixit Pidicrete URP.

APPLICATION

1. Provide the first layer of 150 gsm polyester based geo textile before laying Dr. Fixit Flexshield.

2. Lay the Dr. Fixit Flexshield membrane and allow it to relax for some time.

3. Lay a geotextile of 150 gsm over the membrane for protection of the waterproofing membrane.

4. Bond the laps of the membrane sheets using a seam tape. Overlapping between the two membranes must be at least 75-100mm.

5. Place a geotextile fabric of 150 gsm over the membrane before laying the concrete screed of average 50 mm which will facilitate the reinforcement cage to be assembled, so the RCC raft can be cast over it.

Retaining wall Dr. Fixit Extensa

SURFACE PREPARATION

Clean the surface thoroughly to get rid of all contaminants. Remove all surface imperfections and repair with a polymer modified mortar using Dr. Fixit Pidicrete URP.

APPLICATION

1. Spray on Dr. Fixit Extensa to achieve an average thickness of 2 mm.

2. Fix the dimpled or plain protection board as a protective layer over the dried Dr. Fixit Extensa membrane.

3. Backfilling can be done after installation.

 

CAD Diagram

Technical data Sheet

Dr. Fixit Flexshield

Dr. Fixit Extensa

Pidilite